Bosch LBB1935/20 Power 240w amplifier online shop near me
Functions
Dependability
- The amplifier is protected against overload and short circuits. A temperature-controlled fan ensures high reliability at high output levels and low acoustic noise at lower output levels. An overheat protection circuit switches off the power stage and activates an LED on the front panel, if the internal temperature reaches a critical limit due to poor ventilation or overload.
- The unit operates both on mains power and on a 24 V battery power supply for emergency back up, with automatic switchover.
- For emergency and evacuation use, the following functions are monitored: mains presence, battery present, pilot tone presence, amplifier operation. Front panel LEDs indicate the status of supervised functions. The LEDs of pilot‑tone supervision and battery status can be switched off for general public address use. Failsafe (normally energized) relays are provided for each supervised function. These relays are always active regardless of the switches on the rear panel.
Input
- The amplifier has two balanced inputs with priority control, each with a loop‑through facility. This makes it easy to connect remote systems that require priority control. An additional 100 V line input is provided to connect the amplifier to a 100 V loudspeaker line to provide more power to remote locations.
- Gain or level control is located on the rear of the unit to avoid accidental setting change. A meter with LED‑bar shows the output level.
Output
- The amplifier has 70 V and 100 V outputs for constant voltage loudspeaker systems, and a low impedance output for 8 ohm loudspeaker loads.
- The amplifier has two separate priority controlled 100 V outputs for zones that only need announcements made via the priority input, and for zones that will not receive announcements made via the priority input.
Controls and indicators
Front
- Meter (LED's for: -20, -6, 0 dB and Power ON)
- Battery operation indicator
- Overheat indicator
Back
- Level control input 1
- Level control input 2
- Power button
- Mains switch
Interconnections
Back
- Priority line input 1 (XLR/balanced)
- Line loop‑through 1 (XLR/balanced)
- Program line input 2 (XLR/balanced)
- Line loop‑through 2 (XLR/balanced)
- Priority controlled loudspeaker output terminals
- 24 VDC power supply terminal
- Three loudspeaker direct output terminals
- Two 100 V slave input terminals
- Input 2 enable control terminal
- Input 1 priority control terminal
- Earth connection screw
- Mains socket
Certifications and approvals
- Safety : acc. to EN 60065
- Immunity : acc. to EN 50130‑4
- Emission : acc. to EN 55103-1
- Emergency :acc. to EN 54‑16
Region Regulatory compliance/quality marks
Europe
- DOP : DECL DOP EN54-16-PlenaVAS
- CPR : DECL CPR EN54-16-PlenaVAS
- CE : DECL EC LBB1935/20
Poland
Parts included
- LBB1935/20 Power Amplifier : 1
- Power cord : 1
- Set of 19" mounting brackets : 1
- Safety instructions : 1
- Cable with XLR connector : 1
Technical specifications
Electrical / Mains power supply
- Voltage : 230 VAC, ±10%, 50/60 Hz
- Inrush current : 9 A
- Max power consumption : 760 VA
Battery power supply
- Voltage : 24 VDC +15% / -15%
- Current max : 11 A
Performance
- Output power (rms/maximum) : 240 / 360 W
- Power reduction on backup power : -1 dB
- Frequency response : 50 Hz to 20 kHz (+1 / ‑3 dB at ‑10 dB ref. rated output)
- Distortion : <1% at rated output power, 1 kHz
- S/N (flat at max volume) : >90 dB
- Line inputs : 2 x
- Connector : 3‑pin XLR, balanced
- Sensitivity : 1 V
- Impedance : 20 kohm
- CMRR : >25 dB (50 Hz to 20 kHz)
- Gain : 40 dB
100 V input
- Connector : Screw, unbalanced
- Sensitivity : 100 V
- Impedance : 330 kohm
- Line loop-through output : 2 x
- Connector : 3‑pin XLR
- Nominal level : 1 V
- Impedance : Direct connection to line input
- Loudspeaker outputs : 3 x
- Connector : Screw, floating
- Direct output : 100 V, 70 V, 8 ohm
- Priority only (from input 1) : 100 V or 70 V internally selectable
- Music (non-priority) only : 100 V or 70 V internally selectable
Power consumption
Mains operation
- Max power : 451 W
- -3dB : 340 W
- -6dB : 244 W
- Pilot tone : 55 W
- Idle : 16 W
24 V operation
- Max power : 12.1 A (290 W)
- -3 dB : 11.4 A (274 W)
- -6 dB : 8.1 A (194 W)
- Pilot tone : 1.7 A (41 W)
- Idle : 0.3 A (7 W)
20 kHz -20dB with maximum loudspeaker load
Mechanical
- Dimensions (H x W x D) : 100 x 430 x 270 mm (19" wide, 2U high, with feet)
- Weight : Approx. 12.5 kg
- Mounting : Standalone, 19”rack
- Color : Charcoal
Environmental
- Operating temperature : -10 ºC to +55 ºC (14 ºF to +131 ºF)
- Storage and transport temperature : -40 ºC to +70 ºC (-40 ºF to +158 ºF)
- Relative humidity : <95%
- Acoustic noise level of fan : <48 dB SPL at 1 m (max output)
Ordering information
LBB1935/20 Power amplifier, 1x240W
- 240 W power amplifier in a 2U high 19” case for rack
- mounting or tabletop use.
- Order number LBB1935/20
Services
EWE-PLNAMP-IW 12mths wrty ext. Plena Power Amp
- 12 months warranty extension
- Order number EWE-PLNAMP-IW